On this page
In short
- New pain, swelling or instability in a joint that was replaced years ago should be checked.
- The cause must be found first. Revision without a clear diagnosis rarely helps.
- Infection is ruled out in every painful implant with blood tests and sometimes a fluid test from the joint.
- Revision is a longer and more complex operation than the first one and needs special implants.
Why does an implant fail?
Wear and loosening
After many years the plastic insert wears and the implant can lose its grip on the bone. Pain returns on walking and the joint may feel unstable.
Infection
Germs can reach the implant at the time of surgery or years later through the blood from another infection in the body. The joint becomes painful, warm and swollen.
Instability or dislocation
The knee gives way or the hip comes out of its socket repeatedly.
Fracture around the implant
A fall can break the bone near the implant, especially when the bone is weak.
Stiffness or wrong alignment
The knee does not bend or straighten enough, or the parts were not positioned well.
Warning signs you should not ignore
- Pain in a replaced joint that was comfortable earlier
- Swelling, warmth or redness around the joint
- Discharge from the old wound
- Fever with joint pain
- The joint feels loose or gives way
- The leg looks shorter or turned
Important
Discharge from the wound or fever with a painful implant can mean infection. Do not start antibiotics on your own. They hide the infection and make it harder to identify the germ. See the surgeon first.
Tests before revision
- X-rays of the full joint, compared with the older films if you have them
- Blood tests such as ESR and CRP to look for infection
- Fluid taken from the joint with a needle and sent for cell count and culture
- CT scan when bone loss or implant position has to be studied
- Details of the first operation and the implant used, if available
What the operation involves
The old implant or a part of it is removed with care to save as much bone as possible. Lost bone is rebuilt with metal wedges, cones or bone graft. A revision implant with longer stems is fixed to get a firm hold in healthy bone.
When infection is present, surgery is usually done in two stages. In the first stage the implant is removed, the joint is cleaned and a spacer made of cement with antibiotics is placed. After 6 to 8 weeks of antibiotics, when the infection is controlled, the new implant is fixed in a second operation.
Recovery
Recovery is slower than after the first replacement. Hospital stay is usually 5 to 7 days. Weight on the leg may be limited for some weeks, depending on the bone and the fixation. The results are good when the cause was clear and treated fully, but they depend more on the individual case than in a first time replacement.
Common questions
My knee was replaced 12 years ago and has started to hurt. Does it need revision?
Not always. Pain can come from the back, the hip, the tendons around the knee or a worn plastic insert. An examination, X-rays and blood tests are needed to find the reason. Sometimes changing only the plastic insert is enough.
Can an infected implant be treated with antibiotics alone?
Rarely. Germs form a layer on the metal that medicines cannot enter. If the infection is caught within the first few weeks, a thorough cleaning operation with change of the plastic insert may save the implant. Later infections usually need the implant to be changed.
Was my first surgery done wrongly if I need a revision?
Not necessarily. Every implant has a life. Wear after 15 to 20 years, late infection or a fall can happen after a perfectly done operation.